Solute fluxes from Tacaná volcano-hydrothermal system, Mexico-Guatemala. Implications for estimation of geothermal potential of the deep aquifer.
Abstract:
Each thermal spring feeds a thermal stream that flows into the main drainage of the area, Río Coatán. Solute and heat fluxes from thermal springs of Tacaná volcano are estimated by the chloride-inventory method. The total observed chloride discharge from the thermal springs is estimated as 14.8 g/s and the total measured heat output of ~9.5 MW. Considering a deep fluid temperature of 250°C, the corresponding advective heat transport from the deep reservoirs that feed these springs may be estimate as 26 MW. However, the total chloride output measured in the main drainage (Coatán river) is 4 times higher (~59 g/s) than the measured Cl output of all known thermal springs. This means that other, undiscovered, thermal discharges exist in the area and that the natural heat output through thermal springs at Tacaná is significantly higher and depends on the Cl content and temperatures of the unknown thermal water discharges. If chloride concentration in these unknown springs does not exceed 540 mg/l (the average analyzed Cl in Tacaná springs) and the discharge temperature is 50°C, then the natural heat output can be estimated at least as 22 MW and the corresponding advective heat transport as ~100 MW.