Preliminary Program subject to change
T1024 Removal and Detection of Emerging Contaminants
OverviewAs distribution systems age, they become increasingly vulnerable to water main breaks and system failures that can result in microbiological contamination. Also, deterioration can provide more sites for microbial growth and protection from disinfection. For water systems serving more than 50,000 people in the United States, the average age of the oldest section of the system is more than 50 years. For the largest systems in the country, the average age of the system’s oldest section approaches 100 years. Even new water main installations can be susceptible to leakage and contamination. In addition to the potential for contamination due to water main breaks, water main repair procedures, and external contamination of storage facilities, several other characteristics of distribution systems present scenarios where contamination is a risk. Contamination can be introduced through cross-connections that are not properly protected through cross-connection control and backflow prevention devices and assemblies. Furthermore, intentional contamination has emerged as a concern, particularly since September 11, 2001. There are many points of entry in the distribution system (e.g., service connections and tanks) where a pathogen could potentially be introduced. In fact, water industry professionals have named distribution systems as one of the most likely areas where a contaminant could be intentionally introduced into the nation’s drinking water. The EPA’s National Homeland Security Center in Cincinnati, OH has been working with other federal agencies (e.g. the Centers for Disease Control and Prevention, FBI, and DOD) and water sector organizations (e.g. American Water Works Research Foundation, Water Environment Research Foundation) to improve information on technologies and conduct research for water sector security. This session is intended to understand and present available scientific information and technologies from the public sector and federal agencies to detect contaminants, develop and use monitoring protocols and techniques, and ensure treatment removal effectiveness. Areas of interest in this session include: • Decontamination methods such as flushing, surfactants, co-solvents, organic acids or chelating solutions; solutions designed to decontaminate chemical and biological weapons on surfaces; and enzymes among others. • Detection and verification tests of chemical agents( e.g VX, Sarin, phosgene), biological agents and pathogens in drinking water. For example, a detection technology may be a rapid polymerase chain reaction (PCR) technology capable of detecting biological agents and pathogens in drinking water or a new online chemical and/or biological detection system which supplies real time data for analysis. • Research and data gaps in emerging etection and removal of contaminants, interactions between contaminants and pipe walls, and other contaminants in water distribution systems. For more information, websites are: • www.epa.gov/safewater/security • www.epa.gov/nhsrc • www.epa.gov/ttep • www.waterisac.org.
Primary SponsorTopical 1: Water Resource Conservation: Purification, Reclamation and Reuse (T1)

Chair

Paul M. Randall
Sr. Chemical Engineer
National Risk Management Research Laboratory
U.S. Environmental Protection Agency
26 W. Martin Luther King Drive
Cincinnati, OH 45268
Phone Number: 513-569-7673
Fax Number: 513-569-7105
Email: randall.paul@epa.gov

CoChair

Todd French
Dave C. Swalm School of Chemical Engineering
Mississippi State University
330 Swalm
Mississippi State, MS 39762
Phone Number: 662-325-1456
Fax Number: 662-325-2482
Email: french@che.msstate.edu
Overview of Epa's Water Security Decontamination Research
Paul M. Randall, National Risk Management Research Laboratory, U.S. EPA, 26 West Martin Luther King Dr, Cincinnati, OH 45140
Pilot-Scale Evaluation of Various Approaches for the Decontamination of Drinking Water Distribution Systems
Haishan Piao, SBR Technologies, Inc., 1600 Gest Street, USEPA T&E Facility, Cincinnati, OH 45204, Radha Krishnan, Shaw Group, Inc, 5050 Section Avenue, Cincinnati, OH 45212, Nur Muhammad, Shaw Group, Inc., 1600 Gest Street, USEPA T&E Facility, Cincinnati, OH 45204 and Paul M. Randall, National Risk Management Research Laboratory, U.S. Environmental Protection Agency, 26 W. Martin Luther King Drive, Cincinnati, OH 45268
Contamination and Decontamination of Building Plumbing Systems
Stephen Treado, Building and Fire Research Laboratory, National Institute of Standards and Technology, 226, B114, Gaithersburg, MD 20899
Drinking Water Decontamination with Immobilized Enzymes
Joseph J. DeFrank, BioDefense Team, U.S. Army Edgewood Chemical Biological Center, AMSRD-ECB-RT-BP (Bldg. E-3549), Aberdeen Proving Ground, MD 21010-5424 and Ilona J. Fry, SAIC, P.O. Box 68, Gunpowder, MD 21010
Viability of Nanofiltration and Reverse Osmosis in Removing Emerging Trace Organic Contaminants
Jorg Drewes, Christopher Bellona and Pei Xu, Environmental Science and Engineering, Colorado School of Mines, 1500 Illinois Street, Environmental Science and Engineering, Golden, CO 80401-1887
Molecularly Imprinted Polymers for Estrogenic Pollutants Removal
Ashok Mulchandani, Department of Chemical and Environmental Engineering, University of California, Riverside, Riverside, CA 92521, Zihui Meng, Beijing Institute of Technology, China and Wilfred Chen, Chemical and Environmental Engineering, University of California, Riverside, Bourns Hall A242, University of California, Riverside, Riverside, CA 92521

Topical 1: Water Resource Conservation: Purification, Reclamation and Reuse