| Blood Glucose Regulation Using Stochastic Optimal Control for Insulin Dependent Diabetic Patients | ||
| Saadet Ulas Acikgoz, Department of Bioengineering, University of Illinois at Chicago, 851 S Morgan St, Chicago, IL 60607 and Urmila Diwekar, Center for Uncertain Systems: Tools for Optimization and Management (CUSTOM), Vishwamitra Research Institute, Westmont, IL 60559
20.8 million people in the
The ideal treatment for controlling blood glucose levels in insulin dependent diabetic patients would be the use of an artificial pancreas which would have the following components: (a) a glucose sensor which monitors the blood glucose continuously with sufficient reliability and precision; (b) a computer which could calculate the necessary insulin infusion rates by an appropriate feedback algorithm; (c) an insulin infusion pump which would release the required amount of insulin into the blood. Safe delivery of insulin in this way requires reliable glucose sensors. Two types of sensors have been developed during the last 30 years, minimal invasive and non-invasive (Koschinsky and Heinemann, 2001). The non-invasive approaches are carried out using optical glucose sensors. These sensors work by directing a light beam through intact skin and measuring the properties of the reflected light that are altered either as a result of direct interaction with glucose (spectroscopic approach) or due to the indirect effects of glucose by inducing changes in the physical properties of skin (scattering approach). However, these optical sensors are not able to measure glucose with sufficient precision. On the other hand, minimally invasive sensors measure the glucose concentration in the interstitial fluid of the skin or in the subcutis. There is a free and rapid exchange of glucose molecules and interstitial fluid. Therefore, changes in blood glucose and interstitial glucose are correlated. However, there is a time delay between these changes varying from a few seconds to 15 minutes; which complicates the interpretation of measurement results (Roe and Smoller, 1998). The magnitude of this delay depends on factors such as the absolute glucose concentrations and direction of change. This delay shows intra and inter-individual variability. Furthermore, it has been found that the absolute values of interstitial glucose concentrations vary between 50 and 100% of the intravasal value.
The wide-spread use of these glucose sensors is also complicated by biocompatibility issues and skin reactions. Also these sensors should be available at a reasonable cost in order to be applicable to insulin-dependent diabetic patients. The implementation of a closed loop system in daily life conditions requires these reliability, compatibility, cost and safety issues to be resolved.
A recent study by Campos-Delgado et al. (2006) exploits fuzzy-based strategies to regulate blood glucose levels with a multiple daily injections regimen. A two-loop control structure is adopted for the control scheme to improve glucose regulation. Frequent glucose measurements are needed for this scheme to ensure a faster response to correct insulin scalings and less hypoglycemic conditions. Model predictive control is another strategy that is used to regulate blood glucose (Dua et al., 2006). The optimal insulin delivery rate is obtained off-line as an explicit function of the current blood glucose concentration by using a parametric programming algorithm. This framework also addresses interpatient and intrapatient variability by considering patient dependent parameters as uncertain variables.
The aim of this paper is to develop an optimal control system. Optimal control is different from a closed loop feedback control where the desired operating point is compared with an actual operating point and knowledge of the difference is fed back to the system. Optimal control problems are defined in their time domain, and their solution requires establishing an index of performance for the system and designing the course (future) of action so as to optimize a performance index. Therefore optimal control allows us to make future decisions. Using optimal control theory we can minimize the deviations of blood glucose from non-diabetic levels, while penalizing the use of large amounts of infused insulin for safety. Swan (1982), Fisher and Teo (1989), Ollerton (1989), Fisher (1991) and Parker et al. (1999) applied optimal control theory to this problem. However, uncertainties in model parameters and variability among different individuals were not considered in these papers.
The success of optimal control method depends on the accuracy of the model; therefore, the inherent uncertainties in the patient need to be addressed. If the uncertainties are omitted and if the model cannot accurately represent the glucose and insulin dynamics, this can lead to significant performance degradation. Significant variability of relevant parameters among patients and within a given patient during the course of the day or week has been reported in literature (Simon et al., 1987; Bremer and Gough, 1999). Meals and exercise, the age and weight of the patient also affect the insulin/glucose dynamics. These daily and hourly fluctuations of patient parameters can create difficulties in continuous glucose control. These dynamic uncertainties affect the optimal insulin infusion profiles.
The aim of this paper is to model these uncertainties by a novel approach and incorporating them into formulations of optimal control. Time-dependent uncertainties are commonly encountered in finance literature. Dixit and Pindyck (1994) and Merton and Samuelson (1990) described optimal investment rules developed for pricing options in financial markets, and Ito's Lemma to generalize the Bellman equation or the fundamental equation of optimality for the stochastic case. This new equation constitutes the base of the so called Real Options Theory. Although such a theory was developed in the field of economics, it was recently applied to optimal control problems encountered in other batch chemical processing. (Ulas and Diwekar, 2004; Ulas et al., 2005).
Similarly this approach can be extended to optimal blood glucose control in insulin dependent diabetic patients. The results of this work show that the hourly and daily variations of blood glucose in response to meals and insulin action can be modeled using this methodology and using stochastic maximum principle; optimal insulin infusion profiles can be computed. The stochastic optimal control profile results in fewer variations from the reference blood glucose value of 4.5 mmol/L as compared to the deterministic profile and can potentially be useful in preventing the complications of diabetes.
References
Bremer, T. and Gough, D.A, Diabetes, 48: 445-451, 1999.
Campos-Delgado D.U., Hernandez Ordonez M., Femat R., Gordillo-Moscoso A., IEEE Transactions on Biomedical Engineering, 53(11): 2201-2210, 2006.
Dixit, A.K., and Pindyck, R.S., Investment under Uncertainty,
Dua P., Doyle F.J. III, Pistikopoulos E.N.: Model based glucose control for Type I Diabetes via Parametric Programming, IEEE Transactions on Biomedical Engineering, 53(8): 1478-1491, 2006.
Fisher, M.E. and Teo, K.L., IEEE Transactions in Biomedical Engineering, 36:479-486, 1989.
Fisher, M.E., IEEE Transactions on Biomedical Engineering, 38: 57-61, 1991.
Koschinsky, T. and Heinemann, L., Diabetes Metab. Res. Rev. 17(2):113-23, 2001.
Merton, R. C. and Samuelson, P.A., Continuous-time finance.
Ollerton R.L., International Journal of Control, 50: 2503-2522, 1989.
Parker, R.S., Doyle, III F.J. and Peppas, N.A, IEEE Transactions in Biomedical Engineering, 46(2): 148-157, 1999.
Roe, J.N. and Smoller, B.R., Crit. Rev. Ther. Drug Carrier Syst. 15(3):199-241, 1998.
Simon, G., Brandenberger, G., and Follenius, M., Journal of Clinical Endocrinology & Metabolism, 64: 669-674, 1987.
Swan, G.W., Bulletin of Mathematical Biology, 44: 793-808, 1982.
The DCCT Research Group. The New England Journal of Medicine, 329:977-986, 1993
Ulas, S., and Diwekar, U.M., Computers and Chemical Engineering, 28(11): 2245-2258, 2004.
Ulas, S., Diwekar, U.M., and Stadtherr, M.A., Computers and Chemical Engineering, 29(8): 1805-1814, 2005.
Extended Abstract Status: Not Uploaded | ||