In this instructive asymptotic limit, two decisive dimensionless parameters dictate the steady-state performance of spray combustors; viz., a: 1) Damkohler-like number (ratio of the mean residence time of the chemically reacting mixture in the combustion space, to the reference value of the vaporization lifetime of a SMD- droplet produced by the injector(s)), and 2) non-QS parameter (which increases with gas density and fuel volatility). Illustrative results are generated/displayed here for log-normal feedstream DSDs over a realistic range of spreads.
As discussed, our deliberately idealized mathematical model can be generalized in many ways, but even our present results set instructive bounds to the achievable performance of real spray combustors at high pressures.