Monday, November 9, 2009: 4:30 PM
Canal B (Gaylord Opryland Hotel)
The "Just draw-down" condition is the minimum impeller speed required to ensure that a floating immiscible liquid later (in, for example, a liquid-liquid extraction process) is completely disturbed. Data obtained in a variety of stirred vessel geometries at a range of scales is presented, and performance prediction correlations are compared with those in the literature.
See more of this Session: Mixing in Multi-Phase Systems - Gas-Liquid and Liquid-Liquid Systems
See more of this Group/Topical: North American Mixing Forum
See more of this Group/Topical: North American Mixing Forum