362286 Investigation on the Chemical Degradation of SOFC Anode Caused By the Trace Level of Sulfur and Other Elements Possibly Contained in Coal Derived Fuel Gas
362286 Investigation on the Chemical Degradation of SOFC Anode Caused By the Trace Level of Sulfur and Other Elements Possibly Contained in Coal Derived Fuel Gas
Thursday, November 20, 2014: 12:55 PM
M101 (Marriott Marquis Atlanta)
The integration of gasification and solid oxide fuel cells will be promising direction to meet the demand of clean and efficient utilization of coal for power generation. This study focused on the impact on performance of Ni-YSZ SOFC anode of ppm-level contamination in wet hydrogen or simulated coal syngas (mixtures of H2 and CO). We observed that the trace level contamination of fuel with H2S ranged from 0.02 to 2ppm resulted in the irrecoverable performance loss and slight acceleration of chemical degradation of anode which depended on the concentration of H2S. We also found that the injection of contaminated simulated coal syngas led to the faster degradation compared to the case with hydrogen injection.
See more of this Session: Mercury and Other Trace Elements in Fuel: Emissions, Control, and Measurement II
See more of this Group/Topical: Topical Conference: Advanced Fossil Energy Utilization
See more of this Group/Topical: Topical Conference: Advanced Fossil Energy Utilization