Tuesday, 25 April 2006 - 8:00 AM
88a

Dividing Wall Column Revamp Optimizes Xylene Production

Bernie Slade1, Berne K. Stober1, and Dave Simpson2. (1) Fractionation Technology Group, ExxonMobil Research and Engineering Company, 3225 Gallows Road, Room 8A 0232, Fairfax, VA 22037-0001, (2) Koch-Glitsch, 4411 East 37th Street North, Wichita, KS 67220

The successful revamp of a Xylene Distillation Column is described. The column was a conventional tray column (3800 mm / 4300 mm diameter) taking a xylene sidestream from reformate to feed an aromatics plant to make higher value products. Changing the column configuration to a Dividing Wall Column(DWC) resulted in greater recovery, product purity and significant energy savings. The project cycle is detailed including process design, hydraulic design, mechanical design, manufacture, testing and site work. Economic benefits are outlined and the lessons learned discussed.

See more of #88 - Advances in Distillation Equipment & Applications I (T8002)
See more of Topical 8: Distillation Topical