High Capacity Tray Revamp of a C2 Splitter
Daniel R. Summers, Sulzer, 4019 South Jackson Avenue, Tulsa, OK 74107, Andre Bernard, NOVA Chemicals (Canada) Ltd., 785 Petrolia Line, Corunna, ON N0N 1G0, Canada and Waldo E. De Villiers, Shell Global Solutions (US) Inc., 3333 Highway 6 South, Houston, TX 77082

The NOVA Chemicals (Canada) Ltd. complex located in Sarnia, Ontario, Canada was recently revamped in 2005 to improve the C2 Splitter tower performance. After careful examination of the existing design, desired operation, and future capacity, HiFi™ trays were chosen to replace the old trays. An unusual approach was taken to achieve desired performance. Trays were replaced at larger tray spacings with fewer trays. An increase in tray efficiency was expected and required to achieve the overall performance that was desired after the revamp. After a successful installation, the unit was restarted in late 2005 and desired performance was achieved.

This paper will present the actual operating information for this tower so that others may evaluate the performance, capacity and efficiency of the HiFi tray in C2 Splitter Service.

Extended Abstract Status: File Uploaded

Standard and High-Capacity Trays : Continuing the Heritage of Kunesh, Sakata and Zuiderweg

The Preliminary Program for 2007 Spring National Meeting