208868 Comparison of Deflagration to Detonation Transition (DDT) Criteria with Test Data From Unconfined Ethylene-Air Vapor Cloud Explosion

Monday, March 14, 2011: 3:30 PM
Columbus G/H (Hyatt Regency Chicago)
J. Kelly Thomas, Baker Engineering and Risk Consultants, Inc. (BakerRisk), San Antonio, TX, Jihui Geng, Blast Effects Section, Baker engineering and Risk Consultants, San Antonio, TX and Craig Eastwood, Baker Engineering and Risk Consultants, San Antonio, TX

Deflagration to detonation transitions (DDT) were previously observed in a set of large-scale unconfined vapor cloud explosion (VCE) tests involving ethylene-air mixtures in a moderately congested environment. The test rig congested region was 48 feet long by 12 wide by 6 feet high, with a regular array of vertical circular tubes providing the congestion (pitch-to-diameter ratio of 4.5, area and volume blockage ratios of 22% and 4.1%, respectively). The test rig was configured without any confinement (i.e., no wall or roof sections). The fuel-air mixture completely filled the congested region in these tests, but did not extend beyond it. DDTs were observed at ethylene concentrations ranging from 5.9% (lean) to 9.3% (rich). A comparison has now been made between a DDT criterion established for the FLACS code and this test data. The FLACS DDT criterion utilizes the maximum dimensionless pressure gradient and was established by benchmarking primarily against hydrogen-air tests in confined geometries (i.e., pipes and channels). The comparison with the existing ethylene-air VCE DDT data indicates a different critical value for the maximum dimensionless pressure gradient than that developed based on the confined hydrogen-air tests. Alternative DDT criteria were also explored as part of this work.

Extended Abstract: File Uploaded
See more of this Session: Fires, Explosions and Reactive Chemicals
See more of this Group/Topical: Topical 1: Global Congress on Process Safety