479115 Study on On-Line Monitoring Technology of Oil Tank Grounding
479115 Study on On-Line Monitoring Technology of Oil Tank Grounding
Tuesday, March 28, 2017: 11:15 AM
218 (Henry B. Gonzalez Convention Center)
Abstract: after completion of tank construction, the change of grounding system will be out of people’s sight. The soil resistance will be changed and the metal component will be corroded by acid content in the soil and the grounding resistance will be gradually increased with the time passing by. We have carried out study of on-line monitoring system of grounding resistance to monitor the change of grounding resistance with the seasonal variation. The monitoring system is mainly composed of the grounding resistance acquisition sensor system, wireless or wired network data transmission system and online remote monitoring and recording system, and realized on-line monitoring function of oil tank.
Key words: oil tank; grounding system; grounding resistance; on-line monitoring
See more of this Session: Process Safety Activities in China
See more of this Group/Topical: Global Congress on Process Safety
See more of this Group/Topical: Global Congress on Process Safety