Effective Spectral Emissivity Measurement of Thermally Sprayed YSZ Thermal Barrier Coating at High Temperature Using a Wide-Band Single Wavelength Pyrometer
Ms. Marie Pierre Planche, Larbi Moulla and Christian Coddet, LERMPS, University of Technology Belfort-Montbeliard, Sevenans, Belfort Cedex, 90010, France

Single wavelength pyrometers are widely used for non-contact temperature measurement in areas such as material processing industry, automotive industry or petrochemical industry. In contrast to thermocouples, optical pyrometers have several advantages. First, they are easy to install and second they do not bring any disturbance to the measured system. However, they suffer from some problems, in particular the variation of the material emissivity and perturbations introduced by extraneous radiations. YSZ thermal barriers are known to be more emissive in the 8-14 µm spectral band, therefore we can take advantage using this spectral band in temperature measurement. Spectral emissivities of some YSZ samples were measured and a method for adapting commercial wide-band pyrometers (generally used for low temperature measurements) for high temperature measurements of thermal barrier coatings was tested.

Session 5: Process Diagnostics & Controls 3

The Preliminary Program for International Thermal Spray Conference And Exposition (ITSC) (May 15-18, 2006)