Poly-4-Hydroxybutyrate in the Secondary Breast Implant Patient: Outcome Analysis of 486 Consecutive Procedures

Charles Messa IV, BS, MBA, St. George's University School of Medicine, St. George, Grenada, Jessica Bereszniewicz, BS, St George's University School of Medicine, St. George, Grenada and Charles Messa III, MD, FACS, Weston Cosmetic Surgery Center, Weston, FL
Goals/Purpose:

A significant number of patients who have undergone breast augmentation require a secondary implant procedure to correct implant or soft tissue-related complications. The efficacy of synthetic absorbable mesh (GalaFLEX, Galatea Surgical, BD, Franklin Lakes, NJ, poly-4-hydroxybutyrate, P4HB) to provide internal support for the breast implant and parenchyma in primary and secondary implant procedures has been reported in the literature. However, there are limited studies examining the long-term effectiveness in secondary breast implant patients. The purpose of this study was to evaluate the safety and efficacy of P4HB mesh in secondary breast implant procedures by analyzing long-term complication and reoperation rates and patient satisfaction.

Methods/Technique: s:

A retrospective review was conducted of 486 consecutive secondary breast implant procedures with P4HB scaffold (n=267 patients) performed by a single surgeon from May 2018 to June 2023. All patients had previously undergone breast augmentation or augmentation-mastopexy. All patients underwent a breast implant exchange with P4HB scaffold coverage. Inclusion criteria included a minimum follow-up of 6 months and an anonymously reported practice-generated patient satisfaction questionnaire administered 6 months postoperatively. Demographics and clinical outcomes, including breast implant specifications, indications for breast implant replacement, surgical technique, and post-operative complications were analyzed

Results/Complications:

The mean follow-up was 25 months (range 7 months to 43 months). Mean age of our cohort was 43 years (25 – 70 years) with a mean body mass index of 24.4 kg/m2 (19-32 kg/m2). Primary preoperative indications for breast implant replacement were breast ptosis (n=126), implant malposition (inferior, lateral, medial) (n=49), desire to change implant size (n=34), capsular contracture (n=49), and animation deformity (n=9). Mean time from primary implant surgery to secondary procedure was 5.7 years (10 months to 22 years). Breast implant exchange was bilateral in 96.3% (n=257) and performed with simultaneous mastopexy in 58.8% (n=157), capsulorrhapy in 30.7% (n=82), and capsulectomy in 22.1% (n=59). Silicone implants were utilized in all patients with a mean fill volume of 380cc (range 225cc-600cc) placed in the submuscular or dual plane in 92.5% (n=247). Overall complication rate for all procedures was 6.4% (n=16) with a reoperation rate of 3.4% (n=9). Tissue-related complications occurred in 3.7% (n=10), most commonly recurrent ptosis or pseudoptosis in 1.9% (n=5), and palpability of the scaffold 1.1% (n=3) implant-related complications occurred in 2.7% (n=6), capsular contracture (Baker III or IV) 1.5% (n=4) and superior malposition 0.75% (n=2). The most common indications for reoperation were recurrent ptosis in 2.1% (n= 2), capsular contracture 1.5% (n=4), and implant malposition in 0.75% (n=2) and 3 (1.1%) patients having a secondary procedure to change implant size. No patient required surgery to remove P4HB mesh. There were no cases of peri-prosthetic infection requiring explantation, no seroma formation, no significant skin flap necrosis (>2cm diameter). Regarding patient satisfaction, 97% (n=259) of patients were satisfied or extremely satisfied with the overall appearance of their breasts, including breast shape, size, and symmetry.

Conclusion: s:

This study further validates the safety and efficacy of P4HB scaffold in revision breast implant surgery. Use of P4HB in complicated breast implant procedures is defined by a low complication rate, acceptable aesthetic results, and a reduced number of operations for the patient with high patient satisfaction. An individualized, patient-centric, approach based on a tissue-based assessment potential for soft tissue stretch should be employed for optimal results.